---
product_id: 12207535
title: "Mastercool 63010 50 lb Refrigerant Recovery Cylinder"
price: "B/.921"
currency: PAB
in_stock: true
reviews_count: 13
url: https://www.desertcart.com.pa/products/12207535-mastercool-63010-50-lb-refrigerant-recovery-cylinder
store_origin: PA
region: Panama
---

# Powder-coated corrosion-resistant finish Y-valve for separate liquid & vapor control 50 lb high-strength HP325/HP345 steel Mastercool 63010 50 lb Refrigerant Recovery Cylinder

**Price:** B/.921
**Availability:** ✅ In Stock

## Summary

> 🛠️ Master the cool with precision and power!

## Quick Answers

- **What is this?** Mastercool 63010 50 lb Refrigerant Recovery Cylinder
- **How much does it cost?** B/.921 with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.com.pa](https://www.desertcart.com.pa/products/12207535-mastercool-63010-50-lb-refrigerant-recovery-cylinder)

## Best For

- Customers looking for quality international products

## Why This Product

- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Precision Control with Y-Valve:** Dual 1/4" FL-M fittings enable separate liquid and vapor recovery—boost efficiency and reduce downtime.
- • **Built to Last, Ready to Perform:** Crafted from premium HP325/HP345 steel for unmatched durability and safety under pressure.
- • **Corrosion-Resistant Powder Coat:** Sleek yellow/gray finish protects against wear and tear, keeping your gear looking sharp and professional.
- • **Certified & Factory-Tested Safety:** DOT-4BA400 and CAN/CSA-B339-02 approved, pressure and leak tested for peace of mind on every project.
- • **Universal Refrigerant Compatibility:** Seamlessly handles CFCs, HFCs, HCFCs, and blends like R12, R22, R134a, and R410A—one tank for all jobs.

## Overview

The Mastercool 63010 is a 50 lb refrigerant recovery cylinder built from high-strength HP325/HP345 steel, featuring a Y-valve design for separate liquid and vapor recovery. Its powder-coated finish ensures durability and corrosion resistance. Compatible with all major refrigerants and certified to DOT-4BA400 and CAN/CSA-B339-02 standards, this cylinder is factory-tested for safety and reliability, making it an essential tool for HVAC professionals.

## Description

FEATURES: • Powder coated cylinder for high gloss, durable finish. • Y-valve for liquid and vapor • 3/4” NPT opening accepts 80% fill float switch shut-off device • 1/4” opening for air purge valve • Collar design for ease of handling • Reusable and conforms to DOT-4BA400 specifications and ARI guidelines • Pre-charged cylinder provides a clean, dry interior • Storage and transport of recovered refrigerant gases • Valve & float switch UL listed • TC Canandian approved • NOT FOR USE WITH NITROGEN • All cylinders are pressure and leak tested directly at factory headquarters SPECIFICATIONS: • Size (w x h): 12.25"" x 18.78" • Tare Weight: 28.71 lb. • Standard Specification: DOT-4BA400 • Nominal Water Capacity: 47.7 lb. / 21.6 L • Service Pressure: 400 PSI / 2.7 MPa • Tank Test Pressure: 800 PSI / 5.5 MPa • Relief Valve Pressure: 600 PSI / 4.1 MPa • Air Tightness Pressure: 400 PSI / 2.7 MPa • Body Material: HP325 or HP345

Review: CAN'T BEAT THE PRICE - I've read the other reviews and just keep scratching my head. If the tank has non-condensibles from the factory you must boil them off with a good vacuum pump. And leak check prior to first use. That is standard acceptable practice in the refrigeration field. Just like the system you are working on. You must always vac and leak check any new work prior to filling with refrigerant. If someone got a leaky one from the factory just swap it out for another. I've bought the most expensive tanks available from the supply house and had the same problems noted in these reviews. It happens. I once installed a brand new oil storage tank on a dual-fuel system and discovered a leak in it while being filled. It happens. It's rare. But it happens. At least on a refrigerant recovery tank you can check for leaks prior to using it, unlike the oil storage tank I mentioned. A good vacuum pump should be able to vac to at least 500 microns of non-condensibles which is acceptable for all refrigeration work I'm aware of. If you are using a compound gauge look at the reading below zero when vacuuming. It should go down to at least 28 inches of mercury. (Vacuum can be measured in inches of mercury). If it goes there and stays after you turn your manifold set off for a reasonable period of time you know the tank is leak free. Vacuum isn't affected by changes in temperature like gas or liquid. So it is easy to leak check this way. I learned this the first semester in refrigeration school fellows. If you aren't qualified then steer clear of trying this type work. Get help if necessary. Contaminated refrigerant cannot be re-used. If you plan on re-using the recovered refrigerant in the equipment owned by the same person (which is the only legal way) you must ensure that the refrigerant is okay and you must recover it in a 'clean' fashion. Care must be taken to use a drier/filter and a vacuumed and leak free recovery system including the recovery machine and the tank and hoses. Got it today. vac'd it out with a high vacuum pump and tested for 1/2 hour for leakage based on other reviews. I did note there was a lot of liquid inside but was able to boil it off with the vacuum pump. Found no leak or further liquid boil. Vac held at 28 inches of mercury on my gauge. My practice is to always vac a new thoroughly in case I want to reuse the refrigerant. I then connected the recovery unit and vac'd that and the hoses with the tank valve open. Again no leaks or loss of vacuum. I was then able to start the recovery unit and remove the r-22 in the subject heat pump. No leaks after transferring to the tank. Perfect. Can't complain. The supply house wanted much more for the same thing. Remember, if you want to reuse the refrigerant you must thoroughly vacuum the entire set up including tank, recovery machine and hoses before you begin then leak check. There are no shortcuts in refrigeration work. And you must use a good quality high vacuum pump.
Review: good - value for money, 17.2LB

## Features

- 50 lb empty recovery cylinder constructed with high-strength HP325 or HP345 steel (refrigerant not included).
- Features a Y-valve design with 1/4" FL-M (7/16-20) fittings for secure connections, allowing for separate control of liquid and vapor recovery to enhance efficiency and safety.
- Finished in yellow/gray, with a powder-coated surface for enhanced durability and corrosion resistance.
- Compatible with all types of refrigerants, including CFCs, HFCs, HCFCs, and blends, such as R12, R22, R134a, and R410A.
- DOT-4BA400 and CAN/CSA-B339-02 certified for safe refrigerant storage and transport​. 100% U. S. assembled and tested
- 50 lb. Refrigerant Recovery Tank without Float Switch and 1/4" FL-M (7/16-20)
- Conforms to DOT-4BA400 specs
- Y valve liquid and vapor
- Reusable
- AUS and TC approved

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B00NY1Y0LW |
| Best Sellers Rank | #10,955 in Automotive ( See Top 100 in Automotive ) #2 in Refrigerant Recovery Tools |
| Brand | Mastercool |
| Customer Reviews | 4.6 4.6 out of 5 stars (799) |
| Date First Available | June 14, 2010 |
| Exterior | Steel |
| Item Weight | 30.8 pounds |
| Item model number | 63010 |
| Manufacturer | Mastercool |
| Manufacturer Part Number | 63010 |
| Model | 63010 |
| OEM Part Number | 63010 |
| Product Dimensions | 15 x 19 x 16 inches |

## Product Details

- **Automotive Fit Type:** Universal Fit
- **Brand:** Mastercool
- **Global Trade Identification Number:** 00700376630107
- **Screen Size:** 12.2 Inches
- **UPC:** 700376630107 686109000525

## Images

![Mastercool 63010 50 lb Refrigerant Recovery Cylinder - Image 1](https://m.media-amazon.com/images/I/6105WD2VgHL.jpg)

## Available Options

This product comes in different **Size, Style** options.

## Questions & Answers

**Q: Does the Y valve have 2 1/4 NPT fittings?**
A: The company has the proper adapters you will need to use this for automotive refrigerants. Probably any other adapter you may need also.

**Q: Can you use this tank for either R-410A or R-22? Do you offer a float switch for it?**
A: Yes either R-410A OR R-22.No I do not offer a float switch for it.

**Q: Does this in fact have port for air purge valve as well as port for float switch like the Robinair tanks do?**
A: It has a liquid valve and a vapor valve. It does not have a float in it.

**Q: Does this have a hydro stamp and if not does it need one?**
A: THE HYDRO STAMP IS THE DATE ON TANKS FOR  WHEN TANKS SHOULD BE RETESTED, THEN YES AFTER EVERY 5 YEARS

## Customer Reviews

### ⭐⭐⭐⭐⭐ CAN'T BEAT THE PRICE
*by C***R on January 21, 2014*

I've read the other reviews and just keep scratching my head. If the tank has non-condensibles from the factory you must boil them off with a good vacuum pump. And leak check prior to first use. That is standard acceptable practice in the refrigeration field. Just like the system you are working on. You must always vac and leak check any new work prior to filling with refrigerant. If someone got a leaky one from the factory just swap it out for another. I've bought the most expensive tanks available from the supply house and had the same problems noted in these reviews. It happens. I once installed a brand new oil storage tank on a dual-fuel system and discovered a leak in it while being filled. It happens. It's rare. But it happens. At least on a refrigerant recovery tank you can check for leaks prior to using it, unlike the oil storage tank I mentioned. A good vacuum pump should be able to vac to at least 500 microns of non-condensibles which is acceptable for all refrigeration work I'm aware of. If you are using a compound gauge look at the reading below zero when vacuuming. It should go down to at least 28 inches of mercury. (Vacuum can be measured in inches of mercury). If it goes there and stays after you turn your manifold set off for a reasonable period of time you know the tank is leak free. Vacuum isn't affected by changes in temperature like gas or liquid. So it is easy to leak check this way. I learned this the first semester in refrigeration school fellows. If you aren't qualified then steer clear of trying this type work. Get help if necessary. Contaminated refrigerant cannot be re-used. If you plan on re-using the recovered refrigerant in the equipment owned by the same person (which is the only legal way) you must ensure that the refrigerant is okay and you must recover it in a 'clean' fashion. Care must be taken to use a drier/filter and a vacuumed and leak free recovery system including the recovery machine and the tank and hoses. Got it today. vac'd it out with a high vacuum pump and tested for 1/2 hour for leakage based on other reviews. I did note there was a lot of liquid inside but was able to boil it off with the vacuum pump. Found no leak or further liquid boil. Vac held at 28 inches of mercury on my gauge. My practice is to always vac a new thoroughly in case I want to reuse the refrigerant. I then connected the recovery unit and vac'd that and the hoses with the tank valve open. Again no leaks or loss of vacuum. I was then able to start the recovery unit and remove the r-22 in the subject heat pump. No leaks after transferring to the tank. Perfect. Can't complain. The supply house wanted much more for the same thing. Remember, if you want to reuse the refrigerant you must thoroughly vacuum the entire set up including tank, recovery machine and hoses before you begin then leak check. There are no shortcuts in refrigeration work. And you must use a good quality high vacuum pump.

### ⭐⭐⭐⭐⭐ good
*by E***N on June 18, 2026*

value for money, 17.2LB

### ⭐⭐⭐⭐⭐ Great for contaminated refrigerant (correct colors)
*by J***S on October 5, 2026*

These tanks are used for contaminated refrigerant recovery and work great!

## Frequently Bought Together

- Mastercool 63010 50 lb Refrigerant Recovery Cylinder, DOT-Approved, 1/4" FL-M Connections, HP325/HP345 Steel, Yellow/Gray (No Refrigerant Included)
- Robinair FLCK-1 Filter Conversion Kit for Promax Recovery and Recycling Units, 2 Piece Set
- Robinair (RG3 Portable Refrigerant Recovery Machine – 115V, 60Hz, for Both Liquid and Vapor Refrigerant, White

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.com.pa/products/12207535-mastercool-63010-50-lb-refrigerant-recovery-cylinder](https://www.desertcart.com.pa/products/12207535-mastercool-63010-50-lb-refrigerant-recovery-cylinder)

---

*Product available on Desertcart Panama*
*Store origin: PA*
*Last updated: 2026-10-20*